OLT(241860295) 10:58:43 AW-759006566 OLT(241860295) 10:58:49

High and Low Temperature Test Chambers

Home /Environmental Test Chambers /High and Low Temperature Test Chambers /

High Low Temperature Air Pressure Testing Equipment

hot products

LATEST NEWS

The main function of microreactor

The main function of microreactor

2023-04-22

A microreactor is a small device used for chemical experiments and industrial production. Its main function is to simulate and reproduce the condition

Exquisite craftsmanship, extraordinary performance-90A salt spray test box released to help upgrade quality inspection!

Exquisite craftsmanship, extraordinary performance-90A salt spray test box released to help upgrade quality inspection!

2023-04-15

With the increasing advancement of industrial technology and increasingly stringent environmental regulations, companies have stricter requirements fo

60A Salt Spray Test Chamber - Precise Control, Steadily Improve Your Test Quality

60A Salt Spray Test Chamber - Precise Control, Steadily Improve Your Test Quality

2023-04-07

With the increasing requirements for quality and reliability of industrial products, salt spray testing, as a key link in testing the corrosion resist

Laboratory autoclave

Laboratory autoclave

2023-03-22

Laboratory autoclave (also called autoclave, autoclave or pressure cooker) is a sterilization device widely used in biology, chemistry, medicine, food

High Low Temperature Air Pressure Testing Equipment

  • Model Number:

    OLT-HL-100L
  • Compliance:

    CE Certified
  • Minimum Order Quantity:

    1
  • Capacity:

    100L
  • Voltage:

    108V-380V 50/60HZ
  • Warranty:

    3 year
  • Temperature range:

    -40°C to 150°C
  • Dimension(L*W*H):

    40*50*50 cm
  • Packaging Details:

    Standard export wooden box
  • Delivery Time:

    8-10 day
  • Product Details

High And Low Temperature Test Chamber can test the material property in high and low temperature, such as electrical, electronic products, as well as their original devices, The testing equipment is mainly made according to the national standard and user-defined requirements, it simulate the environment to test proformance of material as well as other relevant characteristics of physical at low temperature or high temperature, Through testing to determine product performance whether it is still be able to meet the intended requirements.


Model

 OLT-HL-80L

OLT-HL-100L  OLT-HL-150L
 Inner size D×W×H  40*50*40 cm  40*50*50 cm  50*60*50 cm
 Index  Temperature  -40°C to 150°C
 Fluctuate/
 uniformly
 ≤±0.5°C /.+2°C to 3°C
 Heating-up time  -40°C to 100°C about 55min
 Cooling time  25°C to -70°C about 80min
 Control
 system 
 Controller  LED digital P,I,D, + S,S,R.microcomputer controller
 Accuracy  Setting accuracy temperature ±0.1°C,directed accuracy temperature ±0.1°C,resolution ±0.1°C
 Sensor  Platinum resistance PT100Ω/MV
 Heating system  Independent system, nickel-chromium alloy electric heating type heater
 Cooling system  Totally enclosed air-cooled single-stage compression refrigerate mode / original from
 Frence "Tecumseh" / totally enclosed air-cooled re-compression refrigerate mode
 Circulatory system   Temperature, low-noise, air-conditioning-type motor. Multi-vane centrifugal wind wheel
 Material   Outer material  High-quality carbon steel plate. Phosphide electrostatic spray treatment /
 SUS304 stainless steel hairline treatment
 Inside material  SUS304 High-quality stainless steel light board
 Insulation material   Rigid polyurethane foam, ultra-fine glass fiber cotton
 Insulation  Double-resistant high-temperature aging of silicone rubber seal
 Standard collocation  a set of Multi-heated glass window attached lighting, testing product shelf 2 pcs,
 test leads holes (25,50 mm) 1 pcs
 Protector  Leak current, short circuit, over temperature, motor overheating, over-pressure
 compressor, overload, over-current protection
 Timer   0.1 to 999.9 (S,M,H) adjustable
 Voltage  AC380V±10%, 50±0.5Hz, Three-phase five-wire system
 Working environment  5°C to 30°C ≤85%R.H


Corresponding standard:
1. GB 10589-89 low temperature testing condition
2. GB 10592-89 high temperature testing condition
3. GB 11158-89 high temperature testing condition
4. GB/T5170.2-1996 basic parameters of environmental testing method for Electrical and   electronic products, 
5. GB2423.1-89 The basic test regulation for electrical and electronic products,  Test A: low-temperature test method
6. GB2423.2-89 The basic test regulation for electrical and electronic products,  Test B: high-temperature test method
7. The basic test regulation for electrical and electronic products,  Test: high-low-temperature test method

Applicable industries:
High And Low Temperature Test Chamberapplied to test the products quality, such as electronic, plastic products, electrical appliances, instruments, food, vehicles, metals, chemicals, building materials, aerospace, medical care and so on.

CE Climatic Environmental simulation Temperature Humidity Test Chamber/Dust Test Chamber

Send Us An Inquiry
We will contact you as soon as possible!
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

RELATED PRODUCTS

Ollital Technology  would like to establish win-win business cooperation with distributors all over the world.