OLT(241860295) 10:58:43 AW-759006566 OLT(241860295) 10:58:49
High quality 1.5L scale lab spray dryer equipment
Lab scale spray dryer is suitable for the production of in universities, research institutes and food and pharmaceutical chemical enterprises.
Model Number:
SC-020Compliance:
CE CertifiedMinimum Order Quantity:
1Voltage:
108V-380V 50/60HZWarranty:
3 yearDimension(L*W*H):
1600*3050*1940mmPackaging Details:
Export wooden packageDelivery Time:
6-8 Day
ASTM B117 Laboratory Nozzle Salt Spray Corrosion Test Chamber is used to test the anti-erosion quality of the surface of all materials after the rust-proof of painting, coating, electroplating, anoding and rust-proof of greasing.anti corrosion treatment for a variety of materials, corrosion resistance of their products.
1.The Laboratory Nozzle Salt Spray Corrosion Test Chamber is made of transparent materials so that the operator can see the tested sample in it and the spraying situation of the tested sample.
2. A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow.
3.Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement.
4.Control System High precision P.I.D. temperature control meter with its error ±0.1°C.
Model |
XB-OLT-60 |
XB-OLT-90 |
XB-OLT-120 |
XB-OLT-160 |
XB-OLT-200 |
Inner size (cm) |
60x45x40 |
90x60x50 |
120x100x50 |
160x100x50 |
200x100x50 |
External size(cm) |
107x60x118 |
141x88x128 |
190x130x140 |
230x130x140 |
270x130x140 |
Inside temp |
Brine test method(NSS ACSS)35°C±1°C/Corrosion resistance test method (CASS)50°C±1°C |
||||
Brine temp |
35°C±1°C 50°C±1°C |
||||
Test chamber volume |
108L |
270L |
600L |
800L |
1000L |
Brine chamber volume |
15L |
25L |
40L |
40L |
40L |
Compressed air pressure
|
1.00±0.01kgf/cm2 |
||||
Spray volume |
1.0~2.0ml/80cm2/h (Collect at least 16 hours, the average) |
||||
Test room relative humidity
|
85%RH or more |
||||
PH |
6.5~7.2 3.0~3.2 |
||||
Spray method |
Programmable spray (including the continuous spray interrupted spray)
|
||||
Power |
AC110V-240V1Φ10A |
AC110V-240V1Φ15A |
AC110V-240V1Φ20A | AC110V-240V1Φ20A | AC110V-240V1Φ30A |
Corresponding Standard:
GB11158 GB10589-89 GB10592-89 GB/T10586-89 GB/T2423.22-2001
GB/T2423.1-2001 GB/T2423.2-2001 GB/T2423.3-93 GB/T2423.4-93 ASTM D1735
IEC60068-2-1.1990 IEC60068-2-2.1974 IEC 68-2-30 IEC68-2-03 EIA - 364-31C
EIA - 364-59 ASTM B117 ASTM G85
Ollital Technology would like to establish win-win business cooperation with distributors all over the world.